SYSTEM OVERVIEW
|
|
Voltage compatibility
|
200, 208, 220, 230, 240V (selectable)
|
|
Frequency compatibility
|
50/60 Hz auto-sensing
|
|
OUTPUT
|
|
Output VA
|
1500
|
|
Output watts
|
1200
|
|
Output nominal voltage
|
200, 208, 220, 230, 240V (selectable)
|
|
Output voltage regulation
|
Full time sine wave output within 2% of selected nominal, 5% max THD
|
|
Output frequency regulation
|
Yes, output is locked to 50/60Hz +/-0.05Hz
|
|
Outlet quantity / type
|
6 IEC-C13
|
|
Customized load management receptacles
|
Includes 2 remotely switchable banks of 3 outlets each, enabling remote reboot of locked network items or load shedding for extended battery runtime. Configurable by included PowerAlert UPS management software.
|
|
Overload protection
|
10A input breaker
|
|
INPUT
|
|
Maximum input amps
|
6.4A
|
|
Input connection type
|
IEC-C14
|
|
Input cord length
|
Unit is packed with one 10 ft. IEC320-C14 to C13 interconnection cable (additional C13 to C14 interconnection cables available, part #P004-006)
|
|
BATTERY
|
|
Full load runtime
|
4.5 min. with internal batteries (1200W)
|
|
Half load runtime
|
12 min. with internal batteries (600W)
|
|
Expandable battery runtime
|
Optional external rack/tower battery packs BP48V24-2U (limit 1) and BP48V60RT-3U (multi-pack compatible)
|
|
DC system voltage
|
48V DC
|
|
Typical battery lifespan
|
Typical lifespan of 3-6 years before battery replacement is required
|
|
Battery recharge rate
|
Recharges internal batteries to 90% in 2-4 hours
|
|
Replacement Battery Cartridge
|
RBC49-2U
|
|
VOLTAGE REGULATION
|
|
Voltage regulation description
|
On-line, double-conversion process give this UPS the ability to maintain output voltage within +/-2% of selected nominal voltage at all times
|
|
Overvoltage correction
|
Maintains continuous operation without using battery power during overvoltage conditions to 275VAC, decreasing output within 2% of selected nominal
|
|
Brownout correction
|
Maintains continous operation without using battery power during brownout / undervoltage conditions to 160VAC, increasing output within 2% of selected nominal
|
|
Severe brownout correction
|
At load levels less than 70%, UPS maintains continuous output during undervoltages to 130VAC, increasing output within 2% of selected nominal
|
|
LEDS ALARMS & SWITCHES
|
|
Front panel LEDs
|
LED STATUS DISPLAY: line power (green), on-line (green), bypass (yellow), on battery (green), overload (red), battery low (yellow) - 4 LED LOAD / BATTERY LEVEL DISPLAY (100%, 75%, 50%, 25%). LED display panel easily rotates for better viewing in rackmount or tower configurations.
|
|
Alarms
|
Multi-function audible alarm offers notification of UPS start, backup operation, low battery warning, overload, UPS fault and remote shutdown
|
|
Switches
|
Includes power off/on switch, plus 1 switch to select battery charge / load level display
|
|
SURGE / NOISE SUPPRESSION
|
|
AC surge suppression
|
480 joules
|
|
AC suppression response time
|
Instantaneous
|
|
EMI / RFI AC noise suppression
|
Yes
|
|
ENVIRONMENTAL
|
|
Operating Temperature
|
+32 to +104 degrees Fahrenheit, 0 to +40 degrees Celsius
|
|
Storage Temperature
|
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
|
|
Relative Humidity
|
0 to 95%, non-condensing
|
|
Audible Noise
|
45dBA At Front Side 1 Meter
|
|
COMMUNICATIONS
|
|
Network monitoring port
|
Includes USB port and DB9 serial port (RS-232 or contact closure). HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X.
|
|
Software and cabling included
|
Includes PowerAlert software CD-ROM and complete cabling
|
|
SNMP compatibility
|
Includes slot for optional SNMPWEBCARD accessory
|
|
WatchDog compatibility
|
Compatible with Tripp Lite's Watchdog software to restore operation to locked equipment through automatic soft reboot of application / OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications
|
|
LINE / BATTERY TRANSFER
|
|
Transfer time from line power to battery mode
|
ZERO, on-line UPS continously converts incoming AC to DC, then back to AC. When commercial power is interrupted, UPS maintains continuous output from battery reserves with absolutely no disruption in output AC power.
|
|
Low voltage transfer to battery power
|
Maintains continuous operation during undervoltages as low as 160V (130V at load levels under 70%). Below the switchover point, output is supported from battery derived AC power.
|
|
High voltage transfer to battery power
|
Maintains continuous operation without using battery power during overvoltages to 275V. Above the switchover point, output is supported from battery derived AC power.
|
|
CERTIFICATIONS
|
|
Certifications
|
CE, SASO, RoHS
|